Skip to content
Evigrade

HOMA-IR calculator online: insulin resistance index, formula, cut-offs

HOMA-IR from fasting insulin and glucose by the Matthews 1985 formula, compared with cut-offs from Spanish adults without diabetes: 2.05, 2.6 and 3.46

Updated · Methodology

µU/mL

About this calculator

HOMA-IR (Homeostatic Model Assessment of Insulin Resistance) is an indirect measure of insulin resistance from a single fasting blood sample. It is used in endocrinology when metabolic syndrome is suspected, in gynecology for polycystic ovary syndrome (PCOS), and in primary care in patients with central obesity, non-alcoholic fatty liver disease or hypertension.

Formula: HOMA-IR = fasting insulin (µU/mL) × fasting glucose (mmol/L) / 22.5. Glucose can be entered in mg/dL and the calculator converts it to mmol/L. Blood is drawn after an 8–12 hour fast. Glucose below 2.5 mmol/L should not be entered into the model: it means hypoglycaemia or an assay problem.

HOMA-IR has no single cut-off. Matthews proposed none in 1985, and published values depend on the population, age, sex and the insulin assay. The calculator compares the result with three cut-offs from Spanish adults without diabetes. The EPIRCE study analysed men and women, with and without diabetes, separately: in men without diabetes the cut-off that best identified people with metabolic syndrome by IDF criteria was 2.05, and in women without diabetes the cut-off depended on age. The 90th percentile in 2246 adults without diabetes from the same study was 3.46. In Ascaso et al. (65 adults aged 30–60 with normal glucose metabolism) the 75th percentile was 2.6. In women over 70 and in women with diabetes, HOMA-IR did not identify people with metabolic syndrome.

To assess one person, Wallace et al. advise using the mean of three insulin samples, since a single fasting sample is unreliable, as Matthews already noted. In people treated with insulin, the model's assumptions about hepatic insulin handling do not hold, and the result needs careful reading.

Source

Matthews DR, Hosker JP, Rudenski AS, et al. Homeostasis model assessment: insulin resistance and beta-cell function from fasting plasma glucose and insulin concentrations in man. Diabetologia 1985;28:412-419. Gayoso-Diz P, Otero-González A, Rodriguez-Alvarez MX, et al. Insulin resistance (HOMA-IR) cut-off values and the metabolic syndrome in a general adult population: effect of gender and age: EPIRCE cross-sectional study. BMC Endocr Disord 2013;13:47. Gayoso-Diz P, Otero-Gonzalez A, Rodriguez-Alvarez MX, et al. Insulin resistance index (HOMA-IR) levels in a general adult population: curves percentile by gender and age. The EPIRCE study. Diabetes Res Clin Pract 2011;94:146-155. Ascaso JF, Pardo S, Real JT, et al. Diagnosing insulin resistance by simple quantitative methods in subjects with normal glucose metabolism. Diabetes Care 2003;26:3320-3325. Wallace TM, Levy JC, Matthews DR. Use and abuse of HOMA modeling. Diabetes Care 2004;27:1487-1495.

How to cite

Vancouver

HOMA-IR calculator [Internet]. Evigrade; 2026 [updated 2026 Oct 21]. Available from: https://www.evigrade.com/en/calculators/homa-ir

APA 7

Evigrade. (2026, October 21). HOMA-IR calculator. https://www.evigrade.com/en/calculators/homa-ir

Related

Calculators